Blolew 35 kV,400–10000 kVA Photovoltaic Combined Transformer

  • Ukuvuselela kwe-Solar Inverter Okufanele Ukuvuselela — Amathuba nezinkotho zokulondoloza zizakhiwe ukusiza kwezinyathelo zokuvuselela ezinamaphuzu amaningi, nokubhekisele kwe-DC.
  • Kwakhiwe emthonjeni, ukuthi kubhekisele kahle — Isikhumba sokugcina konke kuzo; umsebenzi wasekhaya uyakhiwa kuphela emsulwa, emaphutha nekuphatha isikhumbu.
  • Ukubhala kwe-Terminal ne-Ring-Main okufanele — Isithembiso se-Z-terminal noma se-H-ring kuzo zonke izindlela zokubhala kwe-PV plant collector.
  • IP68 Iyabhalwa ngokuphelele ukusetyenziswa kwezindawo zokuphatha amandla we-solar — Ukubhalwa ngokuphelele kwe-50 kPa / 12 amahora; ikhona ukuthi iphathelwe yizibalo, i-UV, isibhamu, ubukhulu be-moisture, nokuguqula kwesikhathi.
  • ukusebenzisa I-Box Ezimbili Ngokwesibonelo — Isithembiso nesiqondiso se-HV kusikhumba esisodwa; ukunciphisa isikhathi sokungasebenzi kwezindawo zokuphatha amandla.
  • ULWAZI
  • Izici
  • Amalungiselelo Angaphakathi
  • Isicelo
  • Iinkcukacha Zokubuyisela
  • Imibuzo Evame Ukubuzwa

U DINGXIN Photovoltaic Combined Transformer yindlela eyenzelwe ukusebenza ngayo umshinana wokugcina emhlabathini ukuphakamisa ukubhala kwe-solar PV kanti Umkhakha we-PV plant ukubhala kwezinto ezihlukene kusukela ku- 400 kVA ku-10000 kVA , ngalunye umshinana uqondisa umshinana wokugcina, izinkampani zokuphakama kwe-high-voltage, izifuse, isitshixo sokuguqula isikhala, nezinkampani zokusebenza ngaphandle kokufakwa kwesikhathi esithile — njengomkhakha wokuphakamisa phakathi kwezinhlobo zokubhala kwe-PV ne-grid yezinkampani zokuphakama.

Umshinana uphakamisa ukubhala kwe-inverter — okwesibonelo 0.27 kV / 0.315 kV / 0.4 kV / 0.69 kV — ku-izindawo zokugcina umkhakha wezindawo zokugcina 10 kV / 35 kV / 38.5 kV , ekwakhiwa ukubambisana ngqo nendawo yamaphutha ephutha yomkhakha wokuphatha amandla we-PV. Amandla okuphakamisa kwaye ayathunyelwa kumsubstation wendawo ngokuthunyelwa kwemithambo emhlabeni noma ngokuthunyelwa kwemithambo emhlabeni.

Ngokuthi ukuphatha amandla we-phutha yomkhakha (photovoltaic) kuyabecala isiqinisekiso esikhulu sezindawo zokuphatha amandla emhlabeni — kusukela kuzindawo zokuphatha amandla okuhle nokusebenza kahle emhlabeni — izindlela zokuphatha amandla ze-DINGXIN PV ziyakhuluma ngokuphelele nezidingo zezindawo zokuphatha amandla we-solar ezintsha:

  • Ukuphakamisa ukuphatha kwe-inverter — iyasebenzisa ukuphatha kwe-harmonic, nokuthi kungaba kunye ne-DC bias yamandla we-inverter ye-PV ngokusebenzisa ukuphatha kwe-winding nokuphatha kwe-insulation.
  • Ukubambisana kwe-collector-line — iyasebenzisa i-terminal (Z) ne-ring-main (H) ukubambisana ukusuka kwezindawo zokuphatha amandla we-PV, futhi iyasebenzisa i-ring-main ukusuka kwezindawo zokuphatha amandla we-PV.
  • Ukubekwa emhlabeni ngokudlula kwesikhathi eside — Isibhakabhaka se-IP68 nezindawo zokugcina ze-IP45 zizokwethula ukubhaleka kwe-UV, amandla, umthelela, nokuguqula kwesikhathi sokuchitha.
  • Kuncane & kubonakalisa ukuthi kuncane ukuthuthukiswa — isibhakabhaka esincane, ukuthuthukiswa okuncane, ukufakwa ngokumelene nokulungisa kuncane, nokuhlanganisa ngokomdla nendawo yezinsuku.

Kubhoni izindlela ezimbili zokubeka isithembiso:

Uhlobo

Incazelo

Kubalulekile kuma

Isibhakabhaka sasekuphakathini esisodwa ngokuphelele

Isitshikilizi nezinqubo zokuphakathi kwe-HV kusibhakabhaka esibezekile ngokuphelele; kuyenza ukulungisa ngokuphelele futhi kuvikela ukuthi amanzi ahlukene angahambisi kusibhakabhaka

Amaphoyisa we-PV amaningi okusebenza okunamandla okukhulu

Isibhakabhaka sesihlangu sesiphothu

Isibhakabhaka sokubhala phansi esingasemthwakweni

Ukubuyekezwa noma ukugxilwa kwezinkambo zokusebenza kwe-PV

Izakhiwo Zamakamelo Ahlukanisiwe

Ukuze kube nemishini emikhulu ye-PV, i-DINGXIN inikeza isakhiwo se-cabine ehlukanisiwe lapho i-high-voltage cabin, i-low-voltage cabin kanye ne-transformer cabin zakha amayunithi amathathu azimele . Iyunithi ye-HV ephumayo ne-LV engenayo ihlukaniswe ngokomzimba kusuka ku-transformer, inikeza ukuphepha nokwethenjelwa okuthuthukisiwe. Ukwakheka kwekhabhinethi kungenziwa uhlobo lwe-mesh, oluqondile (olufana no-I), noma olune-L ukuze ivumelane nesakhiwo kanye nokuqondiswa kwekhebula lokuqoqa kwanoma yisiphi isitshalo se-PV.

  • Ihloselwe umsebenzi we-PV Inverter Step-Up Duty Yakhelwe ngokukhethekile iphrofayela yevolthi, i-harmonic kanye ne-thermal yemikhiqizo ye-inverter yelanga. Umklamo we-Winding kanye nesigaba sokuhlukanisa sichaza amandla okufaka i-DC kanye namandla agcwele ama-harmonic akhiqizwa ama-inverter e-PV agcizelela ukuthi ama-transformer ajwayelekile wokusabalalisa awaklanyelwe ukuphatha.

  • Kwakhiwe emthonjeni, ukuthi kubhekisele kahle I-Transformer, i-HV switchgear, i-fuse, i-tap switch nezinye izinkambo zokusebenza ngaphandle ziyenziwe kwi-enclosure eyodwa futhi zizwetshelwe ngaphandle kwezifundo. Umsebenzi wasekhaya uyakhala kubeka i-foundation, ukuxhuma i-cable, nokufaka isikhathi sokusebenza — okuyishelela isikhathi sokubakha i-PV plant nokholwa kwemisebenzi.

  • I-Terminal esihlukahlukene nezinhlangano zokugcina i-wiring Ababini terminal (Z) kanti ring-main (H) i-wiring schemes zisivumelana, okusiza ekwenzeni i-collector-line esihlukahlukene yezinhlangano zokugcina ezihlukahlukene, ezihlukahlukene noma ezihlukahlukene kwezinhlangano zokugcina zesi-PV plant. Lokhu kusiza ekuphucukiseni i-cable runs nezinhlangano zokugcina ngokuchaza isikhondlo sokubakha nesikhondlo sokugxila kwe-grid.

  • IP68 Iyashiselwe ukusuka kwezinsuku eziningi zokubhekiswa kwezilwane I-tank yenziwe yamaphethu IP68 futhi indawo yonke iyaphasa 50 kPa / 12-hour ukuchitha ukuthi kubhekwe. Indawo ekhuluphileyo iyabhekwa ngokuvikela ukugwala kwe-UV, ukufika kwamandla, ukufika kwamafutha, nokuguqula kokusha kwezinsuku — izinkinga zokuhlelwa kwesibonelo esizimele kakhulu emazweni ethayilandi, ethephu, nasezindaweni eziphakeme zokubeka i-PV.

  • Ukusebenzisa I-Box Ezimbili Ngokwesibonelo Uhlobo lwesibhokisi esisemthethweni sokuqondisa isibhokisi sokuthuthukisa nezinto zokuphakama kuzoba yizindlela ezimbili zokuhlukaniswa, kusiza ukuthi isibhokisi sokuphakama ne-isibhokisi sokuthuthukisa zibe zihlolwe ngokwahlukile . Lokhu kunciphisa isikhathi sokungasebenzi kwezindawo kanye nokunconywa kakhulu kwezindawo zokubeka i-PV zokusebenza kwezinkampani, apho ukusebenza kwezibhokisi zokuthuthukisa kuyaphatha ngqo ukudvuma.

  • Ukubeka kwezindawo zokuhlukaniswa ngezinyathelo zokuvikela ngokugcina amandla Ukubeka kwezindawo zokuhlukaniswa kuyabeka indawo yokuphakama, indawo yokuphansi, ne-indawo yokuthuthukisa njenge izindlela zokuhlukaniswa — apho indawo yokuphakama ne-indawo yokuphansi ziyahlukaniswa ngokwamanqoba kwezindawo zokuthuthukisa ukuthi zibe nzima kakhulu. I zinyathelo zokuvikela ziyagcina amandla ngokugcina amandla , kusiza ukuthi amandla ayavikela ngokuphelele futhi akuvikeli ukungasebenzi kwezinto zokusebenza okusukela kwezindawo zokuhlukaniswa zokuphakama.

  • Ukuphakama Kakhulu, Ukuphula Okuncane, Ukulondoloza Okwengeziwe Kwenziwa ngokusebenzisa ukuphakama okwengeziwe , ukuphula okuncane, nokulondoloza okwengeziwe okugcina ukuphakama kanye nokufana komlilo . I-enclosure isetshenziswa ngokushisa okungavunyelwa ukuthi kubonelela amanzi amanzini kanye nokushisa kwezincwadi zokuvunyela , futhi isebenzisa izinkambiso zokuvunyela — okuzimelela leliqembu ukusebenza emaphakathini angafihliki emazini, emazibini kanye nemaphakathi angafihliki. Ukuzimela kakhulu nesikhathi esifushane sokuxhumana kusiza ukuxhumana kwe-remote monitoring.

Izinqambu Zokuphakama Kwemithombo Yokuqala

Ipharamitha

Ukucaciswa

Ubuzwe lwelulelo<br>

I-Photovoltaic Combined Transformer

Isiphakathi Sokubaluleka Sokugcina

400–10000 kVA (kuya kuma-16000 kVA ngokufuna kwezibhloko ezingcono ze-PV)

Isikhundla Sekuvimba Kwevoltage

≤ 35 kV ne-10 kV (kuya kuma-38.5 kV)

Amavoltage Okuphambili

10 / 35 / 36.75 / 37 / 38.5 kV

Amavoltage Okuphezulu (Okukhuluma Kwesivimba)

0.27 / 0.315 / 0.4 / 0.69 / 0.8 / 0.95 / 1.14 kV

Isibalo sokuqala

50 Hz (60 Hz kungase kubhekwa)

Isikhundla Sekuvimba Kwesitansi

Igoli A

Ukuphakama Kwezinkinga Zokugqibela

≤ 65 K

Ukuphakama Kwezinkinga Zokugqibela Kwemoto

≤ 60 K

Umbhalo

Izinkampani Ezintathu, Izinkampani Ezimbili

Isigaba Sokugqibela

Dyn11

Ukuphatha Kwemfowethu

Ukuhambisa izihlakiso ngaphandle kokusebenza

Ubungako Besiqiniseko

LI200AC85 / AC5 (kubanga izinkampani zezinkampani ze-35 kV)

Isivumelwano Sokugqibela

Isikhombisa (Z) / Isikhombisa Sekhanda (H)

Uhlobo Lwezinkinga

Ithayi le-Sub-Box ephakanyisiwe ngokuphelele / Ithayi le-Sleeve yasePorcelain / Ithayi le-Split-Cabin

Amakhetho wezindlela zokuhlela iCabin

Ithayi le-Mesh / Ithayi le-Linear (I-shaped) / Ithayi le-L-shaped

ithayi le-12 kV Side Outlet

Ithayi le-Prefabricated cable joint + i-arrester eyodwa ngokuthinteka

ithayi le-40.5 kV Side Outlet

Ithayi le-Prefabricated cable joint + i-arrester eyodwa ngokuthinteka

ithayi le-12 kV Fuse Protection

Ithayi le-Plug fuse + i-fuse yokulinda okwengeziwe

ithayi le-40.5 kV Fuse Protection

Ithayi le-Insert dry fuse

Ukuxhuma kwe-HV kwe-Transformer

Ukuxhuma kwe-Busbar (ukusebenza kahle kakhulu)

Umdlalo we-Radiator

Amaphuzu akhululekile ngokugcwele ekupheleni kwesikhathi sokuhlisa kahle kakhulu

Ukuvikela — Isitsha se- Oil

IP68

Ukuvikela — Ikhambu le-HV / LV

IP45

Ukusinda kwe-Sealing

50 kPa / amahora 12 — akukho ukudlula

Ukuzilimela kwe-Enclosure

Ukubhisha okuhlinzekile (okungafani no-seawater / no-salt-spray), umdlalo wokuvikela ukuthwala

Ukusebenzisa izinkampani

Ukusebenzisa izinkampani kakhulu ngezindlela ezihambisana ngokushesha; kufanele kubhekwe kusuka emuva

Imizimbi Yokuseviswa

Ipharamitha

Ukucaciswa

Ukuphakamisa

≤ 3000 m

Umgeni wemvume

−40 °C ukuya ku +45 °C

Umkhondo Wewind Emanjeni

≤ 30 m/s

Ukuphefumula Kwakwesikhathi (Isikhathi Sombili)

≤ 95%

Ukuphefumula Kwakwesikhathi (Isikhathi Seminyaka)

≤ 90%

Umkhondo wokunika umthelela

Umbhalo wokuphakama kahle, izikhathi ezintathu ziyisilinganiso esiphakeme

Amalungiselelo nesibonelo

Standards

Isigaba

IEEE C57.12.00

Izimali Zokusebenza Eziningi Zokugcina Amathransifoma Okugcina, Okunika Umthelela, Nokulungisa

IEEE C57.12.10

Amathransifoma Okunika Umthelela > 500 kVA

IEEE C57.12.34

Amathransifoma Okugcina Esikhwelweni Sokugcina, Esizwe Ngokwesibonelo, Ezintathu Zizikhathi (Isandla Sekunye Sokuqala ≤ 34.5 kV)

IEC 60076-1

Amathransifoma Okunika Umthelela — Eziningi

IEC 60076-2

Amathuba okukhula kwezindawo zokusebenza

IEC 50588

Isifunda sokusebenza kwezindawo zokusebenza ngokuphelele

IEC 62271-202

Amasosha okusebenza okuphelele okwezindawo zokuphakama / ezindaweni eziphansi

GB/T 6451

Isifundo nezimboni zokuziphatha kwezindawo zokusebenza zokuthathu okwesibonelo sokusebenza kwezindawo zokusebenza

GB 20052

Amadlimiti okusebenza kwezindawo zokusebenza nokugcina izigaba zokusebenza kwezindawo zokusebenza

Imiphumela YokuSebenza Kwamandla (35 kV Class Oil-Immersed, PV / Wind / Storage Duty)

Ukukhokhwa Kwamandla (kVA)

Ukuphuma Kwamandla Kwe-NX1 (kW)

Ukuphuma Kwamandla Kwe-NX1 (kW)

Ukuphuma Kwamandla Kwe-NX2 (kW)

Ukuphuma Kwamandla Kwe-NX2 (kW)

Ukuphuma Kwamandla Kwe-NX3 (kW)

Ukuphuma Kwamandla Kwe-NX3 (kW)

1000

0.63

10.35

0.75

10.35

0.86

10.93

1250

0.77

12.51

0.91

12.51

1.05

13.21

1600

0.93

14.94

1.10

14.94

1.27

15.77

2000

1.19

16.47

1.41

16.47

1.49

17.39

2250

1.29

17.06

1.52

17.06

1.68

17.55

2500

1.41

17.64

1.66

17.64

1.77

18.62

2750

1.52

19.05

1.80

19.05

1.98

20.11

3000

1.62

20.29

1.91

20.29

2.13

21.41

3150

1.67

20.70

1.98

20.70

2.21

21.85

3500

1.81

22.36

2.13

22.36

2.43

23.60

3750

1.93

23.60

2.25

23.60

2.58

24.91

4000

2.00

24.60

2.30

24.60

2.61

25.90

4250

2.11

26.08

2.49

26.08

2.88

27.53

4500

2.19

27.12

2.59

27.12

3.03

28.62

4750

2.29

27.66

2.71

27.66

3.10

29.16

5000

2.40

28.20

2.80

28.20

3.15

29.70

6300

2.90

31.50

3.40

31.50

3.78

33.30

8000

4.00

34.60

4.70

34.60

5.22

36.50

10000

4.80

40.80

5.70

40.80

6.30

43.00

12500

5.50

48.40

6.50

48.40

7.20

51.10

16000

6.70

59.20

7.90

59.20

8.73

62.50

NX1 yindlela eya kuthi yinkimbinkibi yokusebenza kwamandla (ukuphuma kwamandla okuncane), ekusiza abasebenzisi base-PV ukuncima ukusebenza kwamandla okungafanele nokugcina izithelo zokugcina amandla emhlabathi ngeminyaka engaphezu kwe-25.

Inkcazelo Yekholi Yomodeli

I-Transformer ehlanganisiwe G (Ibhokisi Lokwabelana) / F (Ibhokisi Elihlukanisiwe) Izigaba Ezintathu Ikhodi Yezinga Lokusebenza Uhlobo Lwesikhungo Ukukhiqizwa Kwamandla E-Photovoltaic Amandla Akhonjisiwe (kVA)

  • Izitshalo ze-PV Zomsebenzi Ukufakwa kwe-inverter okuyisisekelo kanye ne-MV collector-line interface yama-solar farms angu-10 MW kuya ku-500 MW +; i-ring-main wiring ivumela i-topology ye-collector engafuneki.
  • I-PV / Uphahla Lwezentengiselwano Olusakazekile Amayunithi anamandla amancane okufaka i-inverter ezindaweni zokuhweba nezimboni; izintambo zokuqeda ukuze kube nokuxhumeka okulula kwe-radial.
  • Izitshalo ze-PV ze-Streing Inverter Izinguquko eziningi ezincane ezihlanganisiwe ezisabalalisiwe kulo lonke uhla, ngayinye ikhonza iqoqo le-inverter ye-string.
  • Izitshalo Zelanga Ezintantayo (FPV) Isikhwama esivaliwe se-IP68 esenzelwe izindawo ezinomswakama ophakeme, ezakhelene namanzi; ithangi elivaliwe livimbela ukungena komswakama.
  • Amathuba aseDesert — I-enclosure esihlukile ekuthiwe ngemvula, ene-arrester yohlelo lokugcina; isebenza kuzo zonke izinsuku zokuguqula kwesikhathi sokunquma kusukela ku-−10 °C emzulwini ku-+55 °C ngomso.
  • Amathuba aseHigh-Altitude — Iyavamile ukusebenza kwezindawo eziningi kakhulu kune-3000 m; indawo yokuqinisa yonke iyasinda isibonelo sokuphuma kwesithunzi kwezindawo ezingaphansi kwezinye nezinkambiso eziningi.
  • Agrivoltaic (Isithunzi + Ukulima) — Isikhala esincane sisondela ukusetshenziswa kwesithunzi; i-enclosure esivamile kwezindawo zokusha isebenza ngokuhambisana nokulima.
  • Amathuba asePV-Plus-Storage Hybrid — I-transformer eyengeziwe yamathuba asePV yokuvamisa inverter nesistimu yokugcina amandla we-battery (BESS) kwezindawo zokugcina zaseMV.

I-DINGXIN photovoltaic combined transformers ayabhekwa ngokwesifundo sokubeka kwezindawo. Izinketho zokwenza ngokwesifundo zilandelayo ziyatholakala:

Indawo Yokwenza Ngokwesifundo

Izinketho

Indlela eyenziwe

Ukulinganisa kwe-kVA okuthile kweprojekthi ngokufanayo nesayizi yekhabinethi / isibhakabhaka sezindawo

Umvuthi wokuqala / wokwesibili

Amathuluzi we-HV / LV okuthile ngaphakathi kokugcina kwe-35 kV

Isivumelwano Sokugqibela

Iterminal (Z) noma iring-main (H) — noma zombili ngokugcina kwekhabinethi eyodwa

Uhlobo Lwezinkinga

Isibhakabhaka sesandla sokuphepha esifuneka ukusondela (isibhakabhaka sesibili) noma isibhakabhaka sokuphepha esihlukile

Ukuhambanana nokhabinethi

Ukubhekisa kwemithambo ekhethwe ukusiza kweziqu, iziqu zokuphepha noma iziqu zokuhambanana

Ukubeka kwemifushi

Imifushi yokubeka + imifushi yokuphatha (12 kV) noma imifushi yokubeka yesandla (40.5 kV)

Isigaba Sokugqibela

Dyn11, Yyn0 noma izigaba zezivelelo ezinye ngokwespecification yeprojekthi

Isikhundla Sokugcina

±2×2.5% noma ±5% (kubhala kwe-ohm noma kubhala ngokusebenzisa isikhundla sokugcina umbono)

Uhlobo Lweyoil

Iminyama yamaphuza noma amafulidi weester (ayizihlukile kwezinyama, iphuzu eliphezulu — libuyelwe kuzo izindawo ezingahlukeni kwezinyama)

Ukugcina kwesikhundla

Ukugcina okungakho kwezinkokhelo kwezindawo zezilwane zasezintaba, zasekupheleni komlomo wamazwe noma zasezintaba zezilwane zasezintaba

Ukujonga

Ukugcina kwezinkokhelo zokugcina ukuthempela kwezinkokhelo, ukuthempela kwezinkokhelo zokugcina ukuthempela kwezinkokhelo, ukuchaza kwezinkokhelo ezikhiywe kwezinkokhelo zokugcina (DGA) nokuhlanganisa kwe-SCADA

Amaspeciali wezindawo zokuhlala

Amaphathi okugcina ukuthi amaphathi ayisikhundla kwezindawo zokuhlala; ukugcina kwezindawo zokuhlala; ukugcina kwezindawo zokuhlala

Qhagamshela no-DINGXIN nokufakwa kwakho kwezilwane zokuhlala (isithombe sokugcina, ubukhulu bekho, uvuthi lwezindawo, imiphumela yezindawo) ukufaka isibonelo sokugcina.

Umbuzo 1: Iyiphi indlela yokugcina yezilwane zasezintaba (PV)? I-PV combined transformer yilungisele umkhombo wokugcina okuphakeme okwenzelwe amaphoyinti ase-photovoltaic. Iyakhula isiphumo se-inverter kuqondiso lokugcina lomkhakha, futhi iyengeza i-transformer body, i-HV switchgear, i-fuse nezinkambo zokusebenza ngaphandle kwekhasi elinye, okuhlinzekile ukulungisa ukusakazela kwe-collector-line kwezinhlangano zase-grid nezinhlangano zase-distributed PV.

Umbuzo 2: I-PV combined transformer ithinta kanjani nge-distribution transformer eyisisekelo? I-PV combined transformer iyakhiwa ngokuphelele ukusiza kwezinhlangano zase-solar: iyasebenza ngokuphelele ngokubhekisele kweziqu ezithile neziqu zezihlangothi zase-inverter, iyengeza i-HV switchgear neziqu zokulinda i-fuse ngokuphelele ekhasini elinye ukusakazela ngaphandle kwekhasi, futhi iyavumela ukusakazela kwe-collector-line ngokwesibhakabhaka noma ngokwesirhingi. I-distribution transformer eyisisekelo ayinakho leli qondo lokungeza noma ukukhulisa kwezinhlangano zase-solar.

Umbuzo 3: Iziphi izitha zokubeka ezikhona? (1) Izingxenye ze-sub-box ezivalelwe ngokuphelele eziguqula izinto kanye ne-HV emabhokisini amabili ahlukene ukuze zisetshenziswe ngokuzimela. (2) Uhlobo lwebhokisi lokuphuma lomkhono we-porcelain lokufakwa okujwayelekile. Uhlobo oluvikelekile ngokuphelele lunconyiwe ezitshalweni ezintsha ze-PV ezisebenza emphakathini.

Q4: Isiphi isilinganiso sokuvikelwa esinikezwa isembozo? Ithangi likawoyela linamazinga e-IP68 kanti amakamelo e-HV/LV anamazinga e-IP45. Ithangi ngalinye lidlula esivivinyweni sokuvala esingu-50 kPa / amahora angu-12 ukuze kuqinisekiswe ukuvuza kukawoyela okungekho ngaphansi kokuchayeka kwesikhathi eside kwe-UV yangaphandle, uthuli nomswakama.

Q5: Ingabe i-PV transformer ingakwazi ukubhekana nama-inverter harmonics kanye ne-DC injection? Yebo, ngiyajabula. Ama-transformer ahlanganisiwe e-DINGXIN PV aklanyelwe ukuphatha iphrofayili yamanje enama-harmonic amaningi, engaba ne-DC- biased ye-PV inverter outputs. Umklamo we-winding kanye nomkhawulo wokuhlukanisa ubhekene nokucindezelwa okuqondile kokushisa nokushisa kwe-dielectric komsebenzi wokuphakamisa i-inverter yelanga.

Q6: Yiziphi izimo zemvelo iyunithi engamelana nazo? Ukuphakama ≤ 3000 m, izinga lokushisa elingenhla -40 °C kuya ku +45 °C, isivinini somoya ongaphandle ≤ 30 m/s, umswakama wansuku zonke ≤ 95%, isilinganiso senyanga ≤ 90%. Isembozo esivaliwe simelana nokuchayeka isikhathi eside ku-UV, uthuli kanye nokujikeleza kokushisa okujwayelekile ezindaweni eziwugwadule nezishisayo zezitshalo ze-PV.

Ubu 7: Iziphawu ezimangalisayo zizifani nazo izinhlelo? IEEE C57.12.00, IEEE C57.12.10, IEEE C57.12.34, IEC 60076-1, IEC 60076-2, IEC 50588 ne-IEC 62271-202. Izirhwebhu zokuphatha kweziqu zonke nezirhwebhu zokuphatha kweziqu zokuphatha kweziqu ziyatholakala.

Q8: Ingabe i-PV transformer ingenziwa ngezifiso ngama-inverter ahlukahlukene kanye nosayizi wesitshalo? Yebo, ngiyajabula. Amandla abizwayo, amandla aphambili / aphansi, i-terminal noma i-ring-main wiring, iqembu lokuxhuma, ibanga le-tap, uhlobo lwamafutha (amaminerali noma i-ester), nezinketho zokuqapha konke kungenziwa ngezifiso ukuze kuhambisane namazinga we-inverter kusuka ezitshalweni ezincane ze-

Thola Isilinganiso Samahhala

Ummeleli wethu uzokuthinta masisha.
I-imeyili
I-Cellphone noma i-WhatsApp
Igama
Igama Lenkampani
Umyalezo
0/1000

Ukuba ungena ngezimo zonke, vumela thina

Xhumana Nathi

Thola Isilinganiso Samahhala

Ummeleli wethu uzokuthinta masisha.
I-imeyili
I-Cellphone noma i-WhatsApp
Igama
Igama Lenkampani
Umyalezo
0/1000